CMS ECAL monitoring and calibration in LHC Run 2
F. Monti* on behalf of the CMS collaboration
*corresponding author
Full text: pdf
Pre-published on: 2018 September 05
Published on:
Abstract
Precise calibration and monitoring of the CMS electromagnetic calorimeter (ECAL) is a key ingredient in achieving the excellent ECAL performance required by many physics analyses employing electrons and photons. This poster describes the methods used to monitor and inter-calibrate the ECAL response, using physics channels such as W/Z boson decays to electrons and pi0/eta decays to photon pairs, and also exploiting the azimuthal symmetry of the minimum bias events. Results of the calibrations obtained with Run 2 data are presented.
Open Access
Creative Commons LicenseCopyright owned by the author(s) under the term of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.