Main Image
Volume 350 - 7th Annual Conference on Large Hadron Collider Physics (LHCP2019) - Posters
Gain and time resolution of thin Low Gain Avalanche Detectors.
R. del Burgo,* F. Canelli, S. Hidalgo, B. Kilminster, G. Pellegrini, A. Macchiolo, I. Villa Alvarez.
*corresponding author
Full text: pdf
Pre-published on: 2019 September 09
Published on: 2019 December 04
Abstract
The CMS MIP Timing Detector, proposed for the HL-LHC upgrade, will be instrumented with O(10) square meters of ultra-fast Silicon detectors (UFSD) in the forward region. These UFSDs are aimed at measuring the time of passage of each track with a precision of about 30 ps. The sensor that will be used for this task is the low gain avalanche detectors (LGAD). In this contri- bution, we will present the latest results from laboratory measurements on 50 and 35 μm thick LGADs fabricated by CNM, in the framework of the AIDA-2020 project. We will concentrate on the timing performance of the sensors. Additionally the electrical characterisation of the sensor will be discussed.
DOI: https://doi.org/10.22323/1.350.0024
Open Access
Creative Commons LicenseCopyright owned by the author(s) under the term of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.