Main Image
Volume 350 - 7th Annual Conference on Large Hadron Collider Physics (LHCP2019) - Posters
Relative nonlinearity of BRIL luminometers derived from CMS mu scans
A. Babaev* on behalf of the CMS collaboration
*corresponding author
Full text: pdf
Pre-published on: 2019 September 01
Published on:
Abstract
The Beam Radiation Instrumentation and Luminosity (BRIL) Project is devoted to the simulation and measurements of beam conditions and luminosity for CMS. One of the BRIL tasks is the luminosity monitoring and calibration of the detectors to obtain the luminosity. For precise calibration of the luminosity it is important to understand the influence of nonlinear effects on single bunch instantaneous luminosity evaluated from measurements of a luminometer. These proceedings present the method to estimate nonlinearity of a luminometer based on data from $\mu$ scans, which are beam scans performed at conditions optimized for nonlinearity studies.
Open Access