PoS - Proceedings of Science
Volume 358 - 36th International Cosmic Ray Conference (ICRC2019) - NU - Neutrino
Data Quality Monitoring system in the Baikal-GVD experiment
R. Dvornicky*, A.D. Avrorin, A.V. Avrorin, V.M. Aynutdinov, R. Bannash, I.A. Belolaptikov, V.B. Brudanin, N.M. Budnev, G.V. Domogatsky, A.A. Doroshenko, A.N. Dyachok, L. Fajt, Z.A.M. Dzhilkibaev, S.V. Fialkovsky, A.R. Gafarov, K.V. Golubkov, N.S. Gorshkov, T.I. Gress, R. Ivanov, K.G. Kebkal, O.G. Kebkal, E.V. Khramov, M.M. Kolbin, K.V. Konischev, A.V. Korobchenko, A.P. Koshechkin, A.V. Kozhin, M.V. Kruglov, M.K. Kryukov, V.F. Kulepov, M.B. Milenin, R.A. Mirgazov, V. Nazari, A.I. Panfilov, D.P. Petukhov, E.N. Pliskovsky, M.I. Rozanov, E.V. Rjabov, V.D. Rushay, G.B. Safronov, B.A. Shaybonov, M.D. Shelepov, F. Šimkovic, A.V. Skurikhin, A.G. Solovjev, M.N. Sorokovikov, I. Štekl, E.O. Sushenok, O.V. Suvorova, V.A. Tabolenko, B.A. Tarashansky and S.A. Yakovlevet al. (click to show)
Full text: pdf
Pre-published on: July 22, 2019
Published on: July 02, 2021
Abstract
The quality of the incoming experimental data has a significant importance for both analysis and running the experiment. The main point of the Baikal-GVD DQM system is to monitor the status of the detector and obtained data on the run-by-run based analysis. It should be fast enough to be able to provide analysis results to detector shifter and for participation in the global multimessenger system.
DOI: https://doi.org/10.22323/1.358.0874
How to cite

Metadata are provided both in "article" format (very similar to INSPIRE) as this helps creating very compact bibliographies which can be beneficial to authors and readers, and in "proceeding" format which is more detailed and complete.

Open Access
Creative Commons LicenseCopyright owned by the author(s) under the term of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.