PoS - Proceedings of Science
Volume 364 - European Physical Society Conference on High Energy Physics (EPS-HEP2019) - Detector R&D and Data Handling
Real-time alignment and temperature dependency of the LHCb Vertex Detector
B. Mitreska*  on behalf of the LHCb collaboration
Full text: pdf
Pre-published on: September 30, 2020
Published on: November 12, 2020
Abstract
The accuracy of the LHCb Vertex Locator (VELO) position has ensured excellent detector performance, with a track reconstruction efficiency above 98\%, and a vertex resolution along the beam axis of about 70 $\mu$m. The real-time alignment and calibration procedure developed by the LHCb experiment for Run 2 (2015-2018) for the full detector, including the VELO, provided extremely stable conditions during the full data taking period. In 2010, a significant shrinkage of the VELO modules was observed at the operating temperature of -30 degrees with respect to survey measurements made at ambient temperature. This has been confirmed by the following laboratory measurements of different tmeperatures on a single module. In a recent study, using a dedicated LHCb data sample taken over a range of VELO temperatures, the variation of the detector position as a function of temperature has been evaluated. An overview of the VELO alignment procedure and its performance during Run 2 will be presented, with an emphasis on the study of the temperature dependence.
DOI: https://doi.org/10.22323/1.364.0154
How to cite

Metadata are provided both in "article" format (very similar to INSPIRE) as this helps creating very compact bibliographies which can be beneficial to authors and readers, and in "proceeding" format which is more detailed and complete.

Open Access