PoS - Proceedings of Science
Volume 444 - 38th International Cosmic Ray Conference (ICRC2023) - Gamma-ray Astronomy (GA)
Update on the performance of the MAGIC Intensity Interferometer
I. Jimenez-Martinez*, V.A. Acciari, A. Cifuentes, E. Colombo, J. Cortina, C. Delgado Mendez, C. Díaz, M. Fiori, D. Fink, D. Guberman, T. Hassan, É. Lyard, M. Mariotti, G. Martínez, R. Mirzoyan, G. Naletto, T.R. Njoh Ekoume, M. Polo, N. Produit, J.J. Rodríguez-Vázquez, P. Saha, T. Schweizer, R. Walter, C. Wunderlich, L. Zampieri,  The MAGIC Collaboration, H. Abe, S. Abe, J. Abhir, I. Agudo, T. Aniello, S. Ansoldi, L.A. Antonelli, A. Arbet Engels, C. Arcaro, M. Artero, K. Asano, D. Baack, A. Babić, A. Baquero, U. Barres de Almeida, J.A. Barrio, I. Batković, J.R. Baxter, J. Becerra González, W. Bednarek, E. Bernardini, M.I. Bernardos, J. Bernete, A. Berti, J. Besenrieder, C. Bigongiari, A. Biland, O. Blanch, G. Bonnoli, Z. Bosnjak, I. Burelli, G. Busetto, A. Campoy-Ordaz, A. Carosi, R. Carosi, M. Carretero-Castrillo, A.J. Castro-Tirado, G. Ceribella, Y. Chai, A.A. Chilingarian, S. Cikota, J.L. Contreras, S. Covino, G. D'Amico, V. D'Elia, P. Da Vela, F. Dazzi, A. De Angelis, B. De Lotto, A. Del Popolo, M. Delfino, J. Delgado, D. Depaoli, F. Di Pierro, L. Di Venere, D. Dominis Prester, A. Donini, D. Dorner, M. Doro, D. Elsaesser, G. Emery, J. Escudero, L. Fariña, A. Fattorini, L. Foffano, L. Font, S. Fröse, S. Fukami, Y. Fukazawa, R.J. García López, M. Garczarczyk, S. Gasparyan, M. Gaug, J.G. Giesbrecht Paiva, N. Giglietto, F. Giordano, P. Gliwny, N. Godinović, R. Grau Haro, D. Green, J.G. Green, D. Hadasch, A. Hahn, L. Heckmann, J. Herrera, D. Hrupec, M. Hütten, R. Imazawa, T. Inada, R. Iotov, K. Ishio, I. Jiménez Martínez, J. Jormanainen, D. Kerszberg, G.W. Kluge, Y. Kobayashi, P.M. Kouch, H. Kubo, J. Kushida, M. Láinez Lezáun, A. Lamastra, D. Lelas, F. Leone, E. Lindfors, L. Linhoff, S. Lombardi, F. Longo, R. López-Coto, M. López-Moya, A. López-Oramas, S. Loporchio, A. Lorini, B. Machado de Oliveira Fraga, P. Majumdar, M. Makariev, G. Maneva, N. Mang, M. Manganaro, S. Mangano, K. Mannheim, M. Martínez, M. Martínez-Chicharro, A. Mas-Aguilar, D. Mazin, S. Menchiari, S. Mender, S. Mićanović, D. Miceli, T. Miener, J.M. Miranda, M. Molero Gonzalez, E. Molina, H.A. Mondal, A. Moralejo, D. Morcuende, T. Nakamori, C. Nanci, L. Nava, V. Neustroev, L. Nickel, M. Nievas Rosillo, C. Nigro, L. Nikolić, K. Nilsson, K. Nishijima, K. Noda, S. Nozaki, Y. Ohtani, T. Oka, A. Okumura, J. Otero-Santos, S. Paiano, M. Palatiello, D. Paneque, R. Paoletti, J.M. Paredes, L. Pavletić, D. Pavlović, M. Persic, M. Pihet, G. Pirola, F. Podobnik, P.G. Prada Moroni, E. Prandini, G. Principe, C. Priyadarshi, W. Rhode, M. Ribó, J. Rico, C. Righi, N. Sahakyan, T. Saito, S. Sakurai, K. Satalecka, F.G. Saturni, B. Schleicher, K. Schmidt, F. Schmuckermaier, J.L. Schubert, A. Sciaccaluga, J. Sitarek, V. Sliusar, D. Sobczyńska, A. Spolon, A. Stamerra, J. Strišković, D. Strom, M.C. Strzys, Y. Suda, T. Surić, S. Suutarinen, H. Tajima, M. Takahashi, R. Takeishi, F. Tavecchio, P. Temnikov, K. Terauchi, T. Terzić, M. Teshima, L. Tosti, S. Truzzi, A. Tutone, S. Ubach, J. van Scherpenberg, M. Vazquez Acosta, S. Ventura, V. Verguilov, I. Viale, C.f. Vigorito, V. Vitale, I. Vovk, M. Will and T. Yamamotoet al. (click to show)
Full text: pdf
Pre-published on: August 08, 2023
Published on: September 27, 2024
Abstract
In recent years, the MAGIC telescopes have been equipped with a setup that allows its Imaging Atmospheric Cherenkov Telescopes (IACTs) to function as an Intensity Interferometer. The deadtime-free setup includes a 4-channel GPU-based real-time correlator together with optical filters in the 350-450 nm wavelength range and specialized Active Mirror Control (AMC) configurations. This implementation allows MAGIC to perform measurements of the spatial coherence (visibility) of the intensity fluctuations of an object’s starlight over several separations (baselines) and construct a model of said object. The accessible baseline range for MAGIC is ~40-90 m which translates into an angular resolution of 0.5-1 mas. Additionally, thanks to the AMC it can access even smaller baselines, of less than 17 m (which is the diameter of each of both dishes) to measure objects of greater angular size (>1 mas) and even measure the zero-baseline correlation, which is key to calibrate the system. We present the latest measurements that allow us to understand the performance and systematics of our setup and validate our analysis.
DOI: https://doi.org/10.22323/1.444.0728
How to cite

Metadata are provided both in "article" format (very similar to INSPIRE) as this helps creating very compact bibliographies which can be beneficial to authors and readers, and in "proceeding" format which is more detailed and complete.

Open Access
Creative Commons LicenseCopyright owned by the author(s) under the term of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.