To enhance the sensitivity of gravitational wave detectors, it is crucial to reduce noise within the
10 Hz to 10 kHz frequency range. One effective method is to decrease shot noise by increasing
the laser power. This allows for the achievement of noise specifications expected for the upcoming
observation runs of the Advanced Virgo and Advanced LIGO detectors, as well as for third
generation detectors. However, employing a high power laser may result in undesirable effects
known as Parametric Instabilities, impacting the instrument’s efficiency. This phenomenon occurs
when the high power light stored in an optical cavity is scattered into high-order optical modes
by the thermally excited acoustic modes of one of the cavity mirrors. Because of the radiation
pressure, the optical modes can further drive the mechanical mode inducing its exponential growth.
To mitigate the effect, a system has been developed to prevent the triggering of instabilities. Small
oscillators resonating at the critical frequencies and with a low quality factor are attached to the
lateral surface of the mirrors. Due to the coupling effect between the damper’s mode and the
mirror’s mode, the quality factor of the mirror’s mode is reduced, thus allowing for the reduction
of the risk of triggering instabilities. We present the latest results of various types of dampers tested
on a suspended small fused silica substrate placed in a vacuum chamber at room temperature, as
part of the effort to set up dampers for the Advanced Virgo interferometer.