Commissioning of the camera of the first Large Size Telescope of the Cherenkov Telescope Array
Presented by O. Blanch, C. Delgado and T. Saito*  on behalf of I. Batković, J. Becerra Gonzalez, I. Jiménez Martínez, R. Lopez-Coto, M. Martinez, S. Mićanović,  The CTA-LST Project, H. Abe, A. Aguasca, I. Agudo, L.A. Antonelli, C. Aramo, T. Armstrong, M. Artero, K. Asano, H. Ashkar, P. Aubert, A. Baktash, A. Bamba, A. Baquero Larriva, L. Baroncelli, U. Barres de Almeida, J.A. Barrio, I. Batković, J. Becerra González, M. Bernardos, A. Berti, N. Biederbeck, C. Bigongiari, G. Bonnoli, P. Bordas, D. Bose, A. Bulgarelli, I. Burelli, M. Buscemi, M. Cardillo, S. Caroff, A. Carosi, F. Cassol, M. Cerruti, Y. Chai, K. Cheng, M. Chikawa, L. Chytka, J.L. Contreras, J. Cortina, H. Costantini, M. Dalchenko, A. De Angelis, M. de Bony de Lavergne, G. Deleglise, J. Delgado Mengual, D. della Volpe, D. Depaoli, F. Di Pierro, L. Di Venere, C. Díaz, R.M. Dominik, D. Dominis Prester, A. Donini, D. Dorner, M. Doro, D. Elsässer, G. Emery, J. Escudero, A. Fiasson, L. Foffano, M.V. Fonseca, L. Freixas Coromina, S. Fukami, Y. Fukazawa, E. Garcia, R. Garcia López, N. Giglietto, F. Giordano, P. Gliwny, N. Godinovic, D. Green, P. Grespan, S. Gunji, J. Hackfeld, D. Hadasch, A. Hahn, T. Hassan, K. Hayashi, L. Heckmann, M. Heller, J. Herrera Llorente, K. Hirotani, D. Hoffmann, D. Horns, J. Houles, M. Hrabovsky, D. Hrupec, D. Hui, M. Hütten, T. Inada, Y. Inome, M. Iori, K. Ishio, Y. Iwamura, M. Jacquemont, I. Jimenez-Martinez, L. Jouvin, J. Jurysek, M. Kagaya, V. Karas, H. Katagiri, J. Kataoka, D. Kerszberg, Y. Kobayashi, A. Kong, H. Kubo, J. Kushida, G. Lamanna, A. Lamastra, T. Le Flour, F. Longo, R. López-Coto, M. López-Moya, A. López-Oramas, P.L. Luque-Escamilla, P. Majumdar, M. Makariev, D. Mandat, M. Manganaro, K. Mannheim, M. Mariotti, P. Marquez, G. Marsella, J. Martí, O. Martinez, G. Martínez, M. Martínez, P. Marusevec, A. Mas, G. Maurin, D. Mazin, E. Mestre Guillen, S. Mićanović, D. Miceli, T. Miener, J.M. Miranda, L.D.M. Miranda, R. Mirzoyan, T. Mizuno, E. Molina, T. Montaruli, I. Monteiro, A. Moralejo, D. Morcuende, E. Moretti, A. Morselli, K. Mrakovcic, K. Murase, A. Nagai, T. Nakamori, L. Nickel, D. Nieto, M. Nievas, K. Nishijima, K. Noda, D. Nosek, M. Nöthe, S. Nozaki, M. Ohishi, Y. Ohtani, T. Oka, N. Okazaki, A. Okumura, R. Orito, J. Otero-Santos, M. Palatiello, D. Paneque, R. Paoletti, J.M. Paredes, L. Pavletić, M. Pech, M. Pecimotika, V. Poireau, M. Polo, E. Prandini, J. Prast, C. Priyadarshi, M. Prouza, R. Rando, W. Rhode, M. Ribó, V. Rizi, A. Rugliancich, J.E. Ruiz, S. Sakurai, D. Sanchez, T. Šarić, F.G. Saturni, J. Scherpenberg, B. Schleicher, J.L. Schubert, F. Schüssler, T. Schweizer, M. Seglar Arroyo, R.C. Shellard, J. Sitarek, V. Sliusar, A. Spolon, J. Strišković, M.C. Strzys, Y. Suda, Y. Sunada, H. Tajima, M. Takahashi, H. Takahashi, J. Takata, R. Takeishi, P.T. Tam, S. Tanaka, D. Tateishi, L.Á. Tejedor, P. Temnikov, Y. Terada, T. Terzic, M. Teshima, M. Tluczykont, F. Tokanai, D.F. Torres, P. Travnicek, S. Truzzi, M. Vacula, M. Vazquez Acosta, V. Verguilov, G. Verna, I. Viale, C.f. Vigorito, V. Vitale, I. Vovk, T. Vuillaume, R. Walter, M. Will, T. Yamamoto, R. Yamazaki, T. Yoshida, T. Yoshikoshi and D. Zarićet al. (click to show)
Full text: pdf
Pre-published on: July 23, 2021
Published on: March 18, 2022
Abstract
The first Large Size Telescope (LST-1) of the Cherenkov Telescope Array has been operational since October 2018 at La Palma, Spain. We report on the results obtained during the camera commissioning. The noise level of the readout is determined as a 0.2 p.e. level. The gain of PMTs are well equalized within 2% variation, using the calibration flash system. The effect of the night sky background on the signal readout noise as well as the PMT gain estimation are also well evaluated. Trigger thresholds are optimized for the lowest possible gamma-ray energy threshold and the trigger distribution synchronization has been achieved within 1 ns precision. Automatic rate control realizes the stable observation with 1.5% rate variation over 3 hours. The performance of the novel DAQ system demonstrates a less than 10% dead time for 15 kHz trigger rate even with sophisticated online data correction.
DOI: https://doi.org/10.22323/1.395.0718
How to cite

Metadata are provided both in "article" format (very similar to INSPIRE) as this helps creating very compact bibliographies which can be beneficial to authors and readers, and in "proceeding" format which is more detailed and complete.

Open Access
Creative Commons LicenseCopyright owned by the author(s) under the term of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.