PoS - Proceedings of Science
Volume 373 - The 28th International Workshop on Vertex Detectors (Vertex2019) - Large detectors
CMS Inner Tracker Upgrade
P. Luukka*  on behalf of the CMS Tracker Group
Full text: pdf
Pre-published on: February 20, 2020
Published on: September 14, 2020
Abstract
The LHC is preparing an upgrade, which will bring the luminosity of the machine to 5-7 $\times$ $10^{34}$ $\mathrm{ cm^{\text{-}2}s^{\text{-}1} }$ reaching an integrated luminosity of 3000 $\mathrm{ fb^{\text{-}1} }$ by the end of 2037. This High Luminosity LHC (HL-LHC) scenario will require extensive upgrades to the experiments to fully exploit the physics potential of the accelerator. In this so-called Phase-2 upgrade, CMS detector will require improved radiation hardness, higher detector granularity to reduce occupancy, increased bandwidth to accommodate higher data rates, and an improved trigger capability to maintain an acceptable trigger rate. Thus, the entire tracking system will need to be replaced to deal with the HL-LHC environment and to maintain the excellent performance of the current CMS detector.

The Phase-2 Inner Tracker is designed to maintain or even improve the tracking and vertexing capabilities under the high pileup (140 - 200 collisions per bunch crossing) conditions of the HL-LHC. The detectors should have the required radiation tolerance and capability of delivering the desired performance in terms of detector resolution, occupancy, and track separation. The Inner Tracker will be built from thin silicon pixel detectors segmented into pixel sizes of 25 $\times$ 100 $\mu$$\mathrm{ m^2 }$ or 50 $\times$ 50 $\mathrm{ \mu }$$\mathrm{ m^2 } $. It is composed of a barrel part with four cylindrical layers and eight small and four large disc-like structures in each forward direction. The design also includes the possibility to extract and replace the degraded parts of the detector without removing the beam pipe. The Tracker Endcap Pixel detector, installed within the extended space, will enable the measurement of real-time instantaneous luminosity as an added functionality. The extended geometrical coverage of up to $\mathrm{ \eta }$ $<$ 4.0 provides large forward acceptance to mitigate the pileup, particularly in the endcap calorimeters.
DOI: https://doi.org/10.22323/1.373.0008
How to cite

Metadata are provided both in "article" format (very similar to INSPIRE) as this helps creating very compact bibliographies which can be beneficial to authors and readers, and in "proceeding" format which is more detailed and complete.

Open Access
Creative Commons LicenseCopyright owned by the author(s) under the term of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.