MicroMegas modules of type LM2 for the ATLAS Muon Spectrometer upgrade were assembled and tested in JINR. The tests at the cosmic stand included installation of readout cards to collect cosmic muon data.
A dedicated card installation algorithm was developed to keep electronics from electrostatic and mechanical damage. The examples of module cosmic test results such as efficiency maps and data variation with ambient parameters are presented.