$^{60}\rm{Co}$ $\gamma$ Irradiation of a CMS CROC v2 to 1.6 Grad
S. Wagner*,
B. Bentele",
J. P. Cumalat",
C. England",
Z. Franklin",
D. Gadkari",
J. Harris",
M. Herrmann",
P. Kim",
W. Johns",
C. Pollock",
K. Smolenski",
S. Spanier",
J. Thom" on behalf of the Tracker Group of the CMS Collaboration*: corresponding author
Pre-published on:
December 03, 2025
Published on:
—
Abstract
This paper reports the irradiation of the production version of the readout chip for the CMS HL-LHC pixel detector, CROC~v2, to 1.6~Grad using $\gamma$s from a $^{60}$Co source at Sandia National Laboratory. The CROC~v2 was kept powered, configured, and maintained as close as possible to its nominal operating temperature of -20~$^{\rm o}$C during irradiation. Internal chip voltages, pixel response, and diagnostic ring oscillators were continuously monitored, and thresholds were optimized frequently. The CROC~v2 performed according to specifications at 1.6~Grad. Where available, these results will be compared with those for this and earlier iterations of the RD53 readout chip irradiated to a few Grad with lower-energy X-ray sources.
DOI: https://doi.org/10.22323/1.513.0016