LAUROC1 : Liquid Argon Upgrade Read Out Chip
C. De La Taille*, S. Blin, S. Conforti, P. Dinaucourt, G. Martin-Chassard, N. Seguin-Moreau, K. AlKhoury, L. Duflot, N. Morange, L. Serin, S. Simion, H.H. Chen, M. Dabrovski and H. Liu
Pre-published on:
March 11, 2020
Published on:
April 21, 2020
Abstract
The analog front-end readout electronics of the ATLAS Liquid Argon (LAr) Calorimeter will be replaced by a single chip for the phase II of the high luminosity Large Hadron Collider at CERN. The cornerstone of the circuit is the preamplifier which is very demanding in terms of low noise (0.4 nV/√Hz), large dynamic range (up to 10 mA, 16 bits) and precise input impedance (25 or 50 Ohms) to terminate the cables from the detector. LAUROC1 ASIC integrates an innovative architecture to fulfil these requirements. Detailed measurements are presented.
DOI: https://doi.org/10.22323/1.370.0049
How to cite
Metadata are provided both in "article" format (very similar to INSPIRE) as this helps creating
very compact bibliographies which can be beneficial to authors and
readers, and in "proceeding" format
which is more detailed and complete.